Quantcast
Channel: DELL-Daniel My's Activities
Browsing all 2846 articles
Browse latest View live

installing Bitlocker on Raid 5 drives

hi thanks in advance for reading this.i am trying to install BitLocker on our servers:PowerEdge R9004x 6core128Gb ram5 x 2Tb on Perc 6/iconfigured as Raid 5 no spare 3 partitions 1x 350Gb system 1 x...

View Article


RAC0503 and RAC0501 with T620 and H310

I have a T620 with one Perc H310 connected to the backplane.  In the iDrac when I go to storage I get the following error:RAC0501: There are no physical disks to be displayed. 1. Check if the host...

View Article


Resetting DELL FX2 chassis CMC and config data

Hi,I got the steps to reset the FX2 CMC password from www.dell.com/.../resetting-forgotten-administrator-passwordQuestion: Will it only reset the password and not effect any configuration?Thank you.

View Article

Dell server configuration web page not working properly

Recently the web page where we configure and customize Dell PowerEdge servers is not working properly, it takes forever to render any change in selections, and often time after spending too much time...

View Article

PowerEdge 310 HDD swap using Bare Metal Recovery

I have a bare metal backup saved on an internal HDD, External, HDD, and flash drive and am trying to restore to a new dissimilar HDD. 1TB seagate to a 500GB WD. When I boot into windows setup and press...

View Article


Dell poweredge r710 fan speed

Hello! I am pretty new to severs and i just got a poweredge r710. I am running multiple programs but when i do the cpu temps go to around 70-72 which i dont like. If i take the cover off the fans start...

View Article

T430 vs T330

I'm about to purchase a small server to host Quickbooks and SQL express running Win2012r2 Essentials for a custom POS application in a small business office.  All things being equal...

View Article

Cable for Full sized PCI-E raid controller on R720

Hi,I need to add a full sized PCI-E H710P controller to a poweredge R720 that is currently cabled to use a monolithic)mini) controller. I believe all I need to know is the part number for the cable...

View Article


Random Reboot R740

Hello,We currently have a Windows server 2016 Datacenter server failover cluster with two PowerEdge R740 nodes.The hardware configuration of each node is as follows:2x Intel (R) Xeon (R) Silver 4116...

View Article


Healthy (Recovery Partition) and Healthy (OEM Partition) on Dell PowerEdge...

We have purchased Dell PowerEdge R730xd  servers. After the installation we can see the Healthy (OEM Partition) with OS drive on One Server and on Other Server the partition with name Healthy (Recovery...

View Article

Failed Redundancy on RAID 1

Hello, I have a poweredge R210 server with RAID1 implemented and I am seeing the following error in the event logs The device, \Device\Ide\IdePort3, did not respond within the timeout period.In Disk...

View Article

POWER EDGE 2900

Good afternoon , could you support us in the following issue?We have PE2900 , it was woking fine some months ago   then  it was sent to us by airplane  , after receiving it  we turned  it on  and we...

View Article

Image may be NSFW.
Clik here to view.

iDrac Redfish JSON for Drive Serial Number

Howdy!FNG here! ;-)Trying to get Drive SerialNumber from a NonRaid Controller slot, as seen in this redfish schema:I've used iDrac /v1/Systems/System.Embedded.1/Storage/Controllers/NonRAID.Slot.2-1 and...

View Article


T610 reboot hangs on iDRAC error

I have a T610 which has recently started hanging on reboot with the following error:iDrac6 Communication FailureeAlert!  iDrac6 Error...  RebootingAfter a pause it automatically reboots, and the second...

View Article

Intel X550-T2 in PowerEdge R710

Hi! Does anyone know if a R710 can handle an Intel X550-T2 running at 10GB? We recently installed one in an R710 and can only get 1GB connection speeds out of it. Is anyone aware of any technincal...

View Article


VRTX Degraded Disk

This morning I noticed there was a disk in my VRTX that was blinking orange.  So, I removed it, and reinserted it.It appeared to start rebuilding.  I however can find no log of this event in the VRTX...

View Article

SNMP - Dell OMSA Not Accepting connections on localhost

Hello ,I am currently unable to monitoring the  Dell Hardware through our MSP portal. Initially I installed Dell Open Manage as well as installing and configuring SNMP. However when I run an...

View Article


R900: Every replacement drive shows E1810 Fault error

I have an older R900 with a Perc 6/i controller with six 500gb SAS (Seagate ST9500430SS) drives configured in a RAID 5 array.  Recently Drive 0 failed so I replaced it with an identical drive.  The...

View Article

dell r610 hdd still blinking green after rebuild

why is my hdd still blinking green after rebuild?how can i fix this?Can do it with megacli?it is a 2 hdd raid 1megacli -LDInfo -Lall -aALLAdapter 0 -- Virtual Drive Information:Virtual Drive: 0 (Target...

View Article

C2100 won't POST, blinking amber fault led

Hi all, suddenly, my C2100 won't post. I opened it up to take a look and troubleshoot. Upon pressing the power button, I see/hear the fans spin up, the hard drive tray LEDs go green, and then.... it...

View Article
Browsing all 2846 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>